# Standard Operating Procedure (SOP): Line Guiding Application

> This document provide the standard operating procedure for the simple line guiding application. This can be printed, laminated and displayed next to the web guide for easy training to new operators.

**Last updated:** 2026-03-07

**Source:** https://live-roll2roll.pantheonsite.io/documentation/manuals/standard-operating-procedure-sop-line-guiding-application

---

**Document Type:** Manuals

This document provide the standard operating procedure for the simple line guiding application. This can be printed, laminated and displayed next to the web guide for easy training to new operators.

## Transcript

1110 S Innovation Way Dr Standard Operating Procedure Stillwater, OK 74074 Contrast Guiding E: sales@r2r.tech W: ​https://r2r.tech P/F: +1-888-290-3215

These instructions are applicable to the software Version: 3.3c or above.

The operating procedure includes two main steps. Step 1​: Teach the controller to look for the contrasting feature of the web. To do this the user has to go to the setup screen and teach the controller as shown below. ❏ Press the tools icon to enter the setup screen.

❏ Type the password to enable the gear icon that takes you to the main setup screen

Page 1 of 3 All Right Reserved. Copyright © 2019 Roll-2-Roll Technologies LLC. Content subject to change without notice.

❏ Make sure that the contrast mode is selected, if not press the black-white icon once to change to black-green-white. Press the tools icon to enter the control setup screen for the two sensors

❏ Select the contrast position type and move the region of interest using the arrow keys. Then save teaching by pressing the gear icon.

❏ Navigate to the feature of interest, save the teaching and press home.

Step 2​: Set the controller to auto mode so that the actuator can start controlling the web position. Page 2 of 3 All Right Reserved. Copyright © 2019 Roll-2-Roll Technologies LLC. Content subject to change without notice.

❏ Once in home screen set the web guide to automatic mode.

Page 3 of 3 All Right Reserved. Copyright © 2019 Roll-2-Roll Technologies LLC. Content subject to change without notice.

## Downloads

- [Standard Operating Procedure - Line Guiding.pdf](https://live-roll2roll.pantheonsite.io/sites/default/files/2019-07/Standard%20Operating%20Procedure%20-%20Line%20Guiding.pdf)

## Related Products

- SCU
- SCU5
- Compact Web Guiding System
- Wide Web Guides
- Retrofit Kit
- Unwind/Rewind Guide
- Low Profile Web Guides
- Narrow Web Steering Guides

**Tags:** SCU, SCU5, Compact Web Guiding System, Wide Web Guides, Retrofit Kit, Unwind/Rewind Guide, Low Profile Web Guides, Narrow Web Steering Guides

---

## About Roll-2-Roll Technologies

Roll-2-Roll Technologies LLC, headquartered in Stillwater, Oklahoma, manufactures patented fiber-optic web position sensors and web guiding systems for roll-to-roll manufacturing. Products include ODC edge sensors (48mm to 960mm), 1DC all-in-one sensors, SCU-series controllers, and complete web guide systems.

- Website: https://r2r.tech
- Phone: +1 (888) 290-3215
- Email: sales@r2r.tech